使用alertmanager对监控对象进行报警(邮件)二

安装alertmanager

到https://prometheus.io/download/下载alertmanager

blob.png

解压后编辑alertmanager.yml,只实现报警功能,修改如下

global:resolve_timeout: 5m                 smtp_smarthost: 'smtp.163.com:25'smtp_from: '***@163.com'smtp_auth_username: '***@163.com'smtp_auth_password: '******'                  #授权密码smtp_require_tls: false
route:group_by: ['alertname']group_wait: 10sgroup_interval: 10srepeat_interval: 1m                                  #重复间隔,这里设置为1m,生产环境设置为20m-30m左右receiver: 'mail'
receivers:
- name: 'mail'email_configs:- to: '@@@@@@163.com'

启动

nohup ./alertmanager --config.file=/root/alertmanager-0.17.0.linux-amd64/alertmanager.yml &


修改prometheus配置如下(和alertmanager同主机):

alerting:alertmanagers:- static_configs:- targets:- 127.0.0.1:9093    #本机启动Alertmanager因此使用127.0.0.1,也可部署在其他主机
rule_files:- "rules/*.yml"          #设置报警规则文件


添加node普遍报警法规则内容如下:

groups:
- name: general.rulesrules:# Alert for any ×××tance that is unreachable for >5 minutes.- alert: InstanceDownexpr: up == 0for: 1mlabels:severity: errorannotations:summary: "Instance {{ $labels.×××tance }} down"description: "{{ $labels.×××tance }} of job {{ $labels.job }} has been down for more than 5 minutes."

查看prometheus中,Targets状态,此时node  http://192.168.199.221:9100/metrics是up状态

blob.png

将221的node_exporter停掉,再次观察

blob.png


查看Alerts状态

blob.png

稍等片刻收到报警

blob.png


添加内存的报警规则内容如下:

groups:
- name: mem.rulesrules:# Alert for any ×××tance that is unreachable for >5 minutes.- alert: NodeMemoryUsageexpr: (node_memory_MemTotal_bytes - (node_memory_MemFree_bytes+node_memory_Buffers_bytes+node_memory_Cached_bytes )) / node_memory_MemTotal_bytes * 100 > 5for: 1mlabels:severity: errorannotations:summary: "Instance {{ $labels.×××tance }} down"description: "{{ $labels.×××tance }} of job {{ $labels.job }} has been down for more than 5 minutes."

说明:由于是测试使用,将使用率调整为超过5%就报警

重载prometheus。查看prometheus  ui中alert状态

blob.png


查看规则是否生效

blob.png

过片刻,收到报警

blob.png


添加cpu报警规则文件内容如下:

groups:
- name: cpu.rulesrules:# Alert for any ×××tance that is unreachable for >5 minutes.- alert: NodeCpuUsageexpr: 100-irate(node_cpu_seconds_total{job="node",mode="idle"}[5m])*100 > 1for: 1mlabels:severity: errorannotations:summary: "{{ $labels.×××tance }} cpu useage load too high"description: "{{ $labels.×××tance }} of job {{ $labels.job }} has been too hgih for more than 1 minutes."

这里设置阈值为1%,只是测试使用。重载prometheus,过片刻收到报警

blob.png